ReleasedSample report

Bacteriostatic Water

Certificate of Analysis · Lot PL-26082 · 3 ml

Sterile
Membrane filtration · LAL

Test results

6/6 conform
TestMethodSpecificationResult
AppearanceVisualClearConforms
Benzyl alcoholGC-FID0.9 % (0.85 to 0.95 %)0.91 %
pH valuePotentiometry4.5 to 7.05.6
SterilityMembrane filtrationSterileSterile
Bacterial endotoxinsLAL< 0.25 EU/ml< 0.25 EU/ml
Visible particlesVisualNoneNone

Methodology

GC-FID: gas chromatography with flame ionisation detector for determining the benzyl alcohol content against an external standard.

Sterility and endotoxins: membrane filtration and the limulus amebocyte lysate test, respectively.

Remarks

All parameters within specification. Batch released.

Sample report illustrating the report structure. Before market launch all reports will be replaced by test protocols from the accredited laboratory.